Experimental Study on Filtration Rate of Revolving Cross-flow Microfiltration

时间:2008-07-30 来源: School of Environmental Science and Engineering,Shanghai Jiaotong University,Shanghai, 200240, China 作者:Son-il Ri a, Zhen-jia Zhang a , Li-na Chi a, Wei-li Zhou a

Abstract: Experimental investigation of the microfiltration (MF) using an revolving cross-flow membrane filter was conducted under constant pressure difference condition, and different flat membranes made of polyvinyliden difloride (PVDF, 0.1 μm), cellulose acetate (CA, 0.22 μm), sulfonated polyethersulfone (SPES, 0.22 μm) and polyamide (PA, 0.45 μm), respectively, were used in filtration experiments. The dependence of the cross-flow MF rate and the filtrated volume on time were measured on-line. The experimental results showed that the effect of the cross-flow on high viscosity medium was more apparent than that on the low viscosity one.

Keywords: viscosity; microfiltration membrane; cross-flow